TAGUCHI L25 ORTHOGONAL DESIGN
NUMBER OF FACTORS =   6
NUMBER OF LEVELS FOR EACH FACTOR =   5
NUMBER OF OBSERVATIONS = 25

REFERENCE--TAGUCHI, SYS. OF EXP. DES., VOL. 2, PAGE 1173.

NOTE--IF POSSIBLE, THIS (AS WITH ALL EXPERIMENT DESIGNS) SHOULD BE RUN IN RANDOM ORDER (TO ASSIST IN THIS RANDOMIZATION, SEE DATAPLOT'S REFERENCE FILES OF RANDOM PERMUTATIONS).

NOTE--TO READ THIS FILE INTO DATAPLOT-- SKIP 25 READ L25.DAT X1 TO X6 DATE--JUNE 1988

X1X2X3X4X5X6
------
111111
122222
133333
144444
155555
212345
223451
234512
245123
251234
313524
324135
335241
341352
352413
414253
425314
431425
442531
453142
515432
521543
532154
543215
554321